| Home | About Us | Computer Systems | Complete POS System | Remote Monitoring System | Contact |
| Sensaphone 1100 | Sensaphone 2000 | Sensaphone Express | Sensaphone Skymetry | IMS-4000 | SCADA 3000 |
| IMS-4000 Accessories | Sensaphone Products |
| Part # | Description | Price |
![]() Water Detection Sensor FGD-0013 |
Water Detection Sensor - Can be used with all Sensaphone models to detect the presence of water on a horizontal surface. Independently powered by internal lithium batteries. Multiple sensors can be wired in series to a single input. Dimensions: 2.25" x 1.125" x 3.625" | |
| |
||
![]() Tempo Alert FGD-0022 |
Tempo Alert - Can be used with all Sensaphone models to monitor air temperature from -30° to 130° F (-34° to 54° C). Simply determine the acceptable temperature limits for your application by adjusting the temperature limit arms. When temperature exceeds the setting, the sensor triggers an alarm. Can be mounted to any wall or vertical surface. Multiple Temp° Alerts may be wired in parallel to a single input. Dimensions: 6.25" x 3.25" x 2" |
|
| |
||
![]() Humidistat FGD-0027 |
Humidistat - Can be used with all Sensaphone models to detect too high or too low a humidity level. Range of the humidistat is 10% to 60% RH. The sensor causes an alarm when the humidity exceeds or falls below the set limit. Multiple sensors may be wired to a single input. Dimensions: 4.125" x 2.75" x 1.5" |
|
| |
||
![]() Magnetic Reed Switch FGD-0006 |
Magnetic Reed Switch - May be used with all Sensaphone models to detect any unauthorized entry or intrusion. Usually installed on doors and windows, the sensors monitor their opening and closing. Several magnetic reed switches may be wired in series. Dimensions: 2.5" x 0.75" x 0.5" (part with screw terminals) 2.5" x 0.75" x 0.625" (part with magnet) |
|
| |
||
![]() Passive Infra-Red Motion Detector FGD-0007 |
Passive Infra-Red Motion Detector - Can be used with all Sensaphone® models to monitor the movement of warm bodies in a specific area. Will cause a dialout if motion is detected. Range of detection covers approximately 50 ft. of area. Multiple sensors can be wired in series to a single input. Dimensions: 4" x 6" x 1.5" | |
| |
||
![]() Accessory Hook-Up Wire FGD-0010 |
Accessory Hook-Up Wire - 50 ft. of 22-gauge wire used to connect a sensor away from a Sensaphone unit. Appropriate for wiring all the sensors available in this catalog, and for most monitoring applications. | |
| |
||
![]() Isotel Surge Protector FGD-0023 |
Isotel Surge Protector - Protects Sensaphone units from high voltage surges through AC and telephone lines. Includes 4-outlet ISOBAR AC surge and noise protection and 2 built-in RJ11 receptacles for telephone line spike suppression. Features filter isolation, superior noise filtering and Cascade Circuitry filter networks to provide double protection to equipment plugged into the second filter bank. Particularly important in areas of high lightning activity. Dimensions: 2.5" x 3.5" x 6.5" | |
| |
||
![]() Smoke Detector 120VAC FGD-0049 |
Smoke Detector with Built-In Relay - A photoelectric smoke alarm, operating on 120VAC via permanent connection. Has two sets of dry alarm contacts, one form A, SPST, and one form C, SPDT. Horn is included. The detector has tandem interconnect capability (maximum 20). Dimensions: 5.1" diameter x 2.5" Weight: 6.5 ounces | |
| |
||
![]() Smoke Detector 120VAC with Built Backup FGD-0049-B |
Same smoke detector as the FGD-0049 with the addition of a battery backup provision so alarms can still be detected during a power failure. Works with all Sensaphone products. Does not come with wire. | |
| |
||
![]() Humidity Transmitter FGD-0052 |
Humidity Transmitter - Space-mount, low-profile model has 10 point calibration accuracy and features a bulk polymer resistive sensor. 3% accuracy at 20 to 95% RH. Typical drift is less than 1% per year. The sensor output signal is field-selectable from 0-5 volt, 0-10 volt, or 4-20mA. Prewired base makes installation easy. For use with Sensaphone Models: Express II, 2000, ISACC, SCADA 3000. Dimensions: 4.9" x 3.1" (12.4cm x 7.9cm) | |
| |
||
![]() 24VDC Power Supply for FGD-0052 FGD-0053 |
Exclusively for use with the FGD-0052 Humidity Transmitter. Only required if the Sensaphone model does not provide loop power for 4-20mA circuit. | |
| |
||
![]() Power-Out Alert FGD-0054 |
Power-Out Alert - A compact power outage monitoring device to protect against power outages. The Power-Out Alert easily plugs into any 110 VAC receptacle outlet for operation. Connect the SPST output alarm cable to your Sensaphone and prompt notification of the outage will occur after a fixed 3-8 minute delay. The delay guards against nuisance alarms. Dimensions: 2.25" x 2" x 3" (5.7 cm x 5.1 cm x 7.6 cm) | |
| |
||
![]() 2.8K Remote Temperature Sensor FGD-0100 |
2.8K Remote Temperature Sensor - Enables you to monitor temperature at a location away from your Sensaphone unit. Measures and tells you the exact temperature and triggers an alarm when conditions exceed the set high/low limits. May be mounted anywhere air temperature needs to be measured and can be used with all Sensaphone® models. Ranges: For models 1104, 1108, 4100: -20° to 150°F For Express, Express II and ISACC, 2000: -60° to 175°F. Only one sensor may be wired per input. Dimensions: 2.5" x .75" x .75" | |
| |
||
![]() 2.8K & 10K Weatherproof Temperature Probe 2.8K: FGD-0101 10K: FGD-0102 |
2.8K Weatherproof Temperature Probe ( use with 1100 series, 4100, Express, Express II, Model 2000 ) 10K Weatherproof Temperature Probe ( use with Express, Express II, Model 2000, SCADA 3000 ) - Small probes, good general purpose devices for indoor/outdoor applications. Sensitive temperature element in a stainless steel housing with a moisture-resistant seal. Convenient mounting clip and 12’ of wire included. Accurate to +/- 1°F (0.56°C) with a sensing range of -40°F to 175°F. Dimensions: 2" long x 0.25" diameter |
|
| |
||
![]() 10K Immersion Temperature Sensor FGD-0105 |
10K Immersion Temperature Sensor ( use with Express, Express II, 2000, SCADA 3000 ) - Waterproof for measuring the temperature of fluids inside a pipe. 304 stainless steel probe. Brass WEL-B thermowell (screws into customer-supplied 0.5" NPT saddle or Thredolet fitting in pipe). Fits into thermowell via brass 0.125" NPT fitting. Accurate to +/-0.36°F (0.2°C) with a sensing range of 10°F to 230°F. Includes 8' of 24AWG wire. Dimensions: Thermowell 5.125", Sensor in well 6.5" | |
| |
||
Page 1 Next Page |
||
| Back to Model 400 | Back to Model 800 |
| Product Menu |